Description
High-reliability design for stable operation
- The use of high-quality adsorbent particles ensures the stability of the pressure dew point, and the pressure dew point can be achieved up to -40 °C optional.
- Unique compression device is provided to minimize the risk of desiccant powdering
- Well-known branded components are used for durability and reliability
Convenient and practical cabinet design
- Compact cabinet design, easy installation and small footprint
- Aluminum alloy matrix extrusion module is adopted for anti-rust and anti-corrosion
- No pressure vessel inspection is required
- Modular packing package is provided for easy maintenance
Applications
- Food packaging
- Tools and instruments
- Pharmaceutical
- Control systems
- Electronics and semiconductors
- Automobile manufacturing

Standard technical parameters
Pressure dew point: -20 ºC (-40 ºC PDP optional)
Inlet temperature: 2 ~ 50 ºC
Working pressure: 7 bar
Ambient temperature: 2 ~ 45 ºC
Power supply: 230V/1PH/50&60Hz
Technical parameters
| Model | Capacity m3/h | Capacity cfm | Size (mm) | Connection | Pressure Drop (bar) | Electrical Supply | PDP °c |
| SHM10 | 48.6 | 28.6 | 550x350x950 | G 3/4 | 0.04 | 230V-1PH-50/60HZ | -20 |
| SHM15 | 64.8 | 38.1 | 550x350x950 | G 3/4 | 0.04 | 230V-1PH-50/60HZ | -20 |
| SHM20 | 81 | 47.7 | 550x350x950 | G 3/4 | 0.10 | 230V-1PH-50/60HZ | -20 |
| SHM25 | 129.6 | 76.3 | 550x350x1170 | G 3/4 | 0.14 | 230V-1PH-50/60HZ | -20 |
| SHM35 | 162 | 95.4 | 550x350x1480 | G 1 | 0.18 | 230V-1PH-50/60HZ | -20 |
| SHM50 | 243 | 143 | 550x350x1935 | G 1 | 0.30 | 230V-1PH-50/60HZ | -20 |
| SHM60 | 275.4 | 162.1 | 550x330x1170 | G 1 | 0.14 | 230V-1PH-50/60HZ | -20 |
| SHM70 | 324 | 190.7 | 550x330x1480 | G 1-1/2 | 0.18 | 230V-1PH-50/60HZ | -20 |
| SHM80 | 378 | 222.5 | 550x330x1935 | G 1-1/2 | 0.29 | 230V-1PH-50/60HZ | -20 |
| SHM100 | 468 | 275.5 | 550x330x1935 | G 1-1/2 | 0.46 | 230V-1PH-50/60HZ | -20 |
| SHM120 | 576 | 339 | 550x490x1935 | G 2 | 0.29 | 230V-1PH-50/60HZ | -20 |
| SHM140 | 684 | 402.6 | 550x490x1935 | G 2-1/2 | 0.46 | 230V-1PH-50/60HZ | -20 |
Intake temperature correction factor
| Intake air temperature (ºC) | 25 | 30 | 35 | 40 | 45 | 50 |
| Correction factor | 1 | 1 | 1 | 0.84 | 0.67 | 0.55 |
Intake pressure correction factor
| Intake pressure (bar) | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
| Correction factor | 0.62 | 0.75 | 0.87 | 1 | 1.12 | 1.25 | 1.37 |












Reviews